Minimax-Homepage
Sitemap
Search 
 
Company
 
Products
 
Services
 
Infos
 
Contact
 
    Products
    Structural fire protection
    Special solutions
    Fire detection systems
    Fire extinguishers
    Fire extinguishing units
    Emergency plans
    Extinguishants
    Systems for fire vehicles
    Extinguishing water systems
    Powder extinguishing systems
    Foam extinguishing systems
    Foam equipment
    Gas extinguishing systems
    Permanent Intertisation
    Water extinguishing systems
    Fine water spray systems
    Water spray systems
    Sprinkler systems
    Sprinkler components
    Undercover Sprinklers
    and Pipes

Invisible Fire Protection:
Undercover Sprinklers and Pipes

Undercover Anwendung Sprinklers of the Undercover product family from Minimax are the optimum solution for installing in-ceiling systems harmoniously and inconspicuously. They can be used when high aesthetic levels must be maintained, such as in exclusive hotel rooms, museums, department stores or office buildings.

Design-minded architects and builders find sprinkler heads with conventional collars protruding out of the ceiling ugly and bothersome. Due to installation that is almost flush with the ceiling and the selection of a surface finish to match the room, the innovative Undercover sprinklers offer new design possibilities.

Concealed Undercover-sprinklers

Concealed Undercover-sprinklers

Recessed Undercover-sprinklers

Recessed Undercover-sprinklers

Minimax has developed two options - hidden and recessed Undercover sprinklers. Compared to the hidden sprinkler with fine-mesh diaphragm and the new CoverDrop system, the sprinkler head of the recessed Undercover sprinkler can be seen through the decorative ring. Both options are equipped with the hanging, rapid-response umbrella sprinkler - a proven Minimax component.

 

Undercover Kasten The CoverDrop system is based on two redundant working mechanisms. A leaf spring locked with the soldered strut is immobilized within the fine-mesh diaphragm. When the nominal trigger temperature of the soldered strut, which lies below the trigger temperature of the sprinkler, is reached, the leave spring is released and the cover is dropped. If, for some reason, the sprinkler is triggered before it drops out of the cover, the cover is released by the escaping water and even water distribution is guaranteed.

The new undercover pipes, which can be laid directly in concrete ceilings, enable future undercover sprinklers to also protect areas without suspended ceilings. The sprinklers are integrated in a recess in the concrete ceiling using a dummy.

Movie: Undercover Sprinklers and Pipes

Brochure download:

Undercover-Sprinklers * recessed and concealed sprinklers (PDF)


Send a request for more information on 'Sprinkler components'


 