Minimax-Homepage
Sitemap
Search 
 
Company
 
Products
 
Services
 
Infos
 
Contact
 
    Products
    Structural fire protection
    Special solutions
    Fire detection systems
    Fire detection control panels
    Fire detectors
    UniVario industrial detectors
    Special detectors
    Alarm signals
    Door locking system
    Danger management
    Fire extinguishers
    Fire extinguishing units
    Emergency plans
    Extinguishants
    Systems for fire vehicles
    Extinguishing water systems
    Powder extinguishing systems
    Foam extinguishing systems
    Foam equipment
    Gas extinguishing systems
    Permanent Intertisation
    Water extinguishing systems

Our detectors are not just standard.

Minimax special detectors:

Fire smoke detector Helios
Our aspirating detector Helios is highly sensitive, nuisance-safe and self-monitoring. It continuously sucks air probes and measures the light scatter with a strong laser light. 200 times more sensitive than a conventional optical smoke detector it detects even smallest smoke particles, which are invisible to the human eye. Therefore it is the ideal protection for sensitive objects - e.g. medical areas, clean rooms or also cultural institutions where irretrievable values could be destroyed quickly.

Multi-functional detectors
special detector HeliosIf materials with a low thermal up-current in case of a smouldering fire are stored in high rooms, the smoke is transported to the detection area of the smoke detectors very slowly. Just as problematic is the fire detection in difficultly accessible cable ducts or control and computer cabinets. Our multi-functional detectors respond to different burning characteristics due to their combined measuring chamber systems. They actively suck air probes and analyse them in a measuring chamber. Thus, fires are already detected in their initial state.

Bypass detectors
Exhaust air and climatic ducts with higher air speeds can be reliably monitored with bypass detectors. Air probes are permanently taken from the monitored duct via a pipeline and analysed in the measuring chamber. In case of fire - when required - the release of fire protection flaps or the shutdown of air conditioning systems is activated to prevent fire and smoke spreading.


Downloads

Multisensor suction smoke detector Helios TDS as download (PDF)

Multi-sensor aspirating smoke detector AMX 4002 as download (PDF)

SilEx 4000 as download (PDF)

Cyclone monitoring VMX 3001 as download (PDF)


Send a request for more information on 'Special detectors'


 


© 2006 Minimax GmbH & Co. KG · Terms of use / Privacy Policy · Imprint