Minimax-Homepage
Sitemap
Search 
 
Company
 
Products
 
Services
 
Infos
 
Contact
 
    Products
    Structural fire protection
    Special solutions
    Fire detection systems
    Fire detection control panels
    Fire detectors
    UniVario industrial detectors
    Special detectors
    Alarm signals
    Door locking system
    Danger management
    Fire extinguishers
    Fire extinguishing units
    Emergency plans
    Extinguishants
    Systems for fire vehicles
    Extinguishing water systems
    Powder extinguishing systems
    Foam extinguishing systems
    Foam equipment
    Gas extinguishing systems
    Permanent Intertisation
    Water extinguishing systems

We provide detectors for all occasions.

fire detectorsOur program includes many different automatic fire detectors for the detection of different burning characteristics and with different response characteristics. After all, in certain cases a mixed supervision is the most effective protection.

Optical smoke detectors
react on the scattered light caused by smoke aerosols and especially their response to visible smoke is very good. An ideal solution if cold smoke is expected in case of fire, e.g. in case of non-glowing smouldering fires.

Differential maximum heat detectors
respond to a maximum temperature or a defined temperature rise within a certain period of time. The right choice if smoke detectors cannot be used due to the outside ambient conditions, e.g. in hotel kitchens and workshops.

Ionization smoke detectors
detect smallest visible and invisible smoke particles. They are used if glowings or even open flames are expected at an early stage of the fire.

Spark and flame detectors
react on optical radiation and select only small areas of the light spectrum for detection. They are the right choice if a fast development of open flames is expected in case of fire.

Fire gas detectors
detect smallest traces of carbon monoxide, which occurs long before smoke and heat in a burgeoning fire. They are not only ideal for a reliable early fire detection, e.g. in computer centres, but - thanks to their new diaphragm system - can also be used in very dusty and humid industrial areas for the first time.


Downloads

Spark/Flame detectors FUX 3200 L1 UEWA FUX 3200 L1 UEWAEx as download (PDF)

Flame detectors FMX 3511 FMX 3501 Ex as download (PDF)

FUX 3001 and FUX 3001 Ex Spark Detectors FTX 3001 and FTX 3001 Ex Spark Test Detectors as download (PDF)

Spark detector FUX 4000 UEWA as download (PDF)

Spark detectors FUX 3001 DL FUX 3001 DL Ex as download (PDF)

Interactive analogue addressable detector OWMX 95, OMX 95, WMX 95 and IMX 95 as download (PDF)

Multisensor fire gas detector GMX1001CO I and GMX1002CO as download (PDF)

Manual Call Points DMX as download (PDF)

Helios AMX5000 aspirating smoke detector series as download (PDF)


Send a request for more information on 'Fire detectors'


 


© 2006 Minimax GmbH & Co. KG · Terms of use / Privacy Policy · Imprint